Disconnector RD(Z)-35/1000 three-pole

1301000
Disconnectors of the RD(Z) type are manufactured in accordance with TU U 27.1-37611511-004:2022, DSTU EN 62271-102:2016 and are designed to switch on and off de-energised sections of the electrical circuit under voltage of 35 kV and above, as well as earthing switches that are integral with the disconnectors. Details
PRODUCT CATALOG

Disconnectors of the RD(Z) type are manufactured in accordance with TU U 27.1-37611511-004:2022, DSTU EN 62271-102:2016 and are designed to switch on and off de-energised sections of the electrical circuit under voltage of 35 kV and above, as well as earthing switches that are integral with the disconnectors.

The disconnectors are available in single-pole, two-pole and three-pole versions. The pole to which the actuator is connected is the leading pole. The actuators are designed to operate the disconnectors. The drive shafts of the main circuit and the earthing circuit rotate:

– manually by means of PR-2B drives;

– automatically by means of PD-14 motor drives (or analogues).

 

Specifications
Nominal voltage, kV 35 
Maximum operating voltage, kV 40.5
Nominal current, A 1000 
Nominal frequency, Hz 50
Nominal short-circuit current (thermal withstand current), kA 25
Maximum peak withstand current (electrodynamic withstand current), kA 63
Nominal duration of the nominal short-circuit current (short-circuit time), s:
– for main contacts
– for grounding contacts
3
1
Mass of one pole, kg 58
Electrical insulation strength meets the requirements for disconnectors of 35 kV voltage class according to GOST 1516.3-96.

The leakage distance of the external insulation of disconnectors on porcelain insulators is:
– with insulation for pollution degree I(A) – not less than cm
– with insulation for pollution degree II(B) – not less than cm

75
105 
Leakage distance of the external insulation of disconnectors on polymer insulators for pollution degree III – not less than cm 125

The disconnectors are designed to operate under the following conditions:

– Altitude above sea level up to 1000 m;
– Ambient temperature ranging from -45 to +40°C;
– Average relative air humidity of 80% at a temperature of +15°C;
– Maximum wind pressure of 700 Pa (corresponding to a wind speed of 34 m/s) without ice formation;
– Maximum wind pressure of 140 Pa (wind speed of 15 m/s) when ice formation on the surface reaches a thickness of up to 10 mm.
– Maximum total mechanical load on the outputs of one pole (from connected conductors, considering wind loads and ice formation) is 500 N under the condition of its uniform distribution on the outputs.

The disconnectors are not intended for operation under severe shocks, vibrations, or impacts.

Performance
Article no. Product name Performance
1301001 Disconnector RD-35/1000 UHL1 three-pole on a common frame (hot zinc) To buy
1301002 Disconnector RDZ-1a-35/1000 UHL1 three-pole on a common frame (hot zinc) To buy
1301003 Disconnector RDZ-1b-35/1000 UHL1 three-pole on a common frame (hot zinc) To buy
1301004 Disconnector RDZ-2-35/1000 UHL1 three-pole on a common frame (hot zinc) To buy